SGI Ethernet Card Dokumentacja Strona 29

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 154
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 28
SG Series Programming Ethernet Features, Functions and Specifications
M550129-03 Rev G 4-5
4.3.5 Readback Resolution
SGA SGI
Voltage 0.002% of full scale 0.02% of full scale
Current 0.002% of full scale 0.02% of full scale
4.3.6 Readback Accuracy
SGA SGI
Voltage ± (0.1% of full scale output voltage)
± (0.1% + 0.15% of
maximum output voltage)
Current*
± (0.25% of full scale output current)
*
± (0.1% + 0.4% of
maximum output current)
* After 30 minutes operation with fixed line, load, and temperature.
Note: Refer to the applicable power supply manual (SGA or SGI) for effects
of line regulation, load regulation, and temperature on accuracy
specifications.
Przeglądanie stron 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 153 154

Komentarze do niniejszej Instrukcji

Brak uwag