Installing MIS JBOD Enclosures
007-5923-001 23
the sides of the rack. The brackets combine with a vertical 6x16 metric hex flange bolt to make
the D-Rack Stiffener assembly.
Note: Installation and use of the D-Rack Stiffener assembly is important because of the extremely
heavy system weights that can occur with SGI NAS JBOD configurations.
Figure 2-6 D-Rack Stiffener Example
Due to their construction, it is easiest to attach the outer bracket to the rack first, before joining
with the inner bracket to make the D-Rack Stiffener.
1. Attach the outer bracket of the D-Rack Stiffener to the D-Rack using the four support
screws. There are six holes available for the screws, but two will be blocked. Use the
remaining four holes.
Note: The screws that attach the D-Rack Stiffener to the rack can be tightened all the way.
2. Attach the inner bracket to the outer bracket using the vertical bolt and socket wrench
(Figure 2-7). Do not tighten these bolts all the way. They will be used later for altering rail
aligning using the alignment tool.